Back to wizard
F
FanucGeneral Series CNC
917 — Alarm 917 (DRAM PARITY) Diagnostic Tree
1
Step 1 / 1
Check the exact alarm message displayed on the screen; if the message is 'DRAM PARITY: (BYTE 5)', a RAM parity error has occurred in the DRAM module, in which case replace the DRAM module with a new one.