Back to wizard
F
FanucGeneral Series CNC
918 — Alarm 918 (DRAM PARITY) Diagnostic Tree
1
Step 1 / 1
Check the exact alarm message displayed on the screen; if the message is 'DRAM PARITY: (BYTE 6)', a RAM parity error has occurred in the DRAM module, in which case replace the DRAM module with a new one.
Need professional support or original spare parts?
With 25+ years of CNC industry experience, I provide brand-independent on-site support and original spare parts services.