Back to wizard
F
FanucGeneral Series CNC
PS5074 — Alarm PS5074 Diagnostic Tree
1
2
Step 1 / 2
Check the program block that caused the alarm to see if the same address is specified two or more times, or if two or more G codes from the same group are specified in the same block, and correct the NC program by removing the duplicates.