0142 — Alarm 0142 (ILLEGAL SCALE RATE) Diagnostic Tree
1
Step 1 / 1
Check the scaling rate in the NC program (G51 P or I, J, K commands) or parameters 5411 and 5421, and correct the scaling magnification to be within the allowable valid range (1 to 999999).