Back to wizard
F
FanucSeries 0i
5329 — Alarm 5329 (M98 AND NC COMMAND IN SAME BLOCK) Diagnostic Tree
1
Step 1 / 1
Check the NC program to verify if a subprogram call (M98) and another NC command are specified in the same block during a canned drilling cycle, and correct the program by separating them into different blocks if they are.