3EALARM 3E — MAGNETIC POLE POSITION DETECTION ERROR

1
2
3
4
5
6
Step 1 / 6
Verify the setting value of servo parameter SV094 (Magnetic pole position error detection speed). If it is not set to the standard value, set SV094 to 10 for both rotary and linear motors, then turn the NC and drive unit power OFF and ON to reset the alarm.