M01 0024 — Alarm M01 0024 (R-pnt ret invld at abs pos alm) Diagnostic Tree
1
2
Step 1 / 2
This error occurs because the reference point (absolute position) definition for the commanded axis is not completed. Perform the absolute position initialization / reference point setting procedure for the affected axis.