Back to wizard
S
SiemensSINUMERIK
22064 — Alarm 22064 ([Channel %1:] Axis %2 reference point approach: zero marker search velocity (MD) is too high) Diagnostic Tree
1
2
3
4
Step 1 / 4
Reduce the zero marker search velocity via machine data MD34040 $MA_REFP_VELO_SEARCH_MARKER.
Need professional support or original spare parts?